EFORT Open Reviews 2018 3:5, 149-159

Uncemented short stems in primary total hip arthroplasty

Mattia Loppini and Guido Grappiolo
Hip
  • Over the last two decades, several conservative femoral prostheses have been designed. The goals of conservative stems include: the spearing of the trochanteric bone stock; a more physiological loading in the proximal femur reducing the risk of stress shielding; and to avoid a long stem into the diaphysis preventing impingement with the femoral cortex and thigh pain.

  • All stems designed to be less invasive than conventional uncemented stems are commonly named ‘short stems’. However, this term is misleading because it refers to a heterogeneous group of stems deeply different in terms of design, biomechanics and bearing. In the short-term follow-up, all conservative stems provided excellent survivorship. However, variable rates of complications were reported, including stem malalignment, incorrect stem sizing and intra-operative fracture.

  • Radiostereometric analysis (RSA) studies demonstrated that some conservative stems were affected by an early slight migration and rotation within the first months after surgery, followed by a secondary stable fixation. Dual-energy x-ray absorptiometry (DEXA) studies demonstrated an implant-specific pattern of bone remodelling.

  • Although the vast majority of stems demonstrated a good osseointegration, some prostheses transferred loads particularly to the lateral and distal-medial regions, favouring proximal stress shielding and bone atrophy in the great trochanter and calcar regions.


Link to article