Knee
  • Total joint arthroplasty (TJA) is one of the most common orthopaedic procedures. Nevertheless, several complications can lead to implant failure.
  • Peri-prosthetic joint infections (PJI) certainly represent a significant challenge in TJA, constituting a major cause of prosthetic revision. The surgeon may have an important role in reducing the PJI rate by limiting the impact of significant risk factors associated to either the patient, the operative environment or the post-operative care.
  • In the pre-operative period, several preventive measures may be adopted to manage reversible medical comorbidities. Other recognised pre-operative risk factors are urinary tract infections, intra-articular corticosteroid injections and nasal colonisation with Staphylococcus (S.) aureus, particularly the methicillin-resistant strain (MRSA).
  • In the intra-operative setting, protective measures for PJI include antibiotic prophylaxis, surgical-site antisepsis and use of pre-admission chlorhexidine washing and pulsed lavage during surgery. In this setting, the use of plastic adhesive drapes and sterile stockinette, as well as using personal protection systems, do not clearly reduce the risk of infection. On the contrary, using sterile theatre light handles and splash basins as well as an increased traffic in the operating room are all associated with an increased risk for PJI.
  • In the post-operative period, other infections causing transient bacteraemia, blood transfusion and poor wound care are considered as risk factors for PJI.