Ceramic-on-ceramic articulation has the lowest wear with little osteolysis. However, the wear and osteolysis in long-term follow-up are not known. Another concern is ceramic fracture, which might occur after repeated stress during a long period. Ninety hips (76 patients with a mean age of 47 years) that underwent cementless total hip arthroplasty using third-generation ceramic-on-ceramic articulation were followed for 14–16 years. At final follow-up, there was no measurable ceramic wear and no periprosthetic osteolysis was identified. No ceramic fracture occurred during the follow-up. One hip was revised because of late infection. All prostheses were bone-ingrown. Two patients experienced a grinding sensation. However, no patient had squeak. The mean Harris hip score at the final evaluation was 89 points and the survival rate was 98.9%.
CoxaPro
> Clinical Library > Welcome to the joint replacement clinical library > Third-Generation Alumina-on-Alumina Total Hip Arthroplasty: 14 to 16-Year Follow-Up Study
The Journal of Arthroplasty, Volume 30, Issue 3, 411 - 415
Hip
Third-Generation Alumina-on-Alumina Total Hip Arthroplasty: 14 to 16-Year Follow-Up Study
Kang, Bun-Jung et al.Hip