The weighted kappa values for the COMI-knee single items ranged from 0.80 to 0.89 and the ICC for the COMI-knee (composite score), 0.86. The absolute SEM for COMI-knee was 0.4 points, i.e. four percent of the maximum value (10 points) and six percent of the average value (6.6 points). The Area Under the Curve derived from the Receiver Operating Characteristic method for the COMI-knee was 0.97 (95% CI, 0.93 to 0.99), with a cut-off value for indicating a “good” result of 2.3 (100% specificity, 87% sensitivity). Correlations between the COMI-knee and the OKS were −0.72 at baseline and −0.87 at six months. The correlations between the change scores for the COMI-knee and the change scores for the OKS and EQ5D index were 0.77 and 0.69, respectively.