Biomed Res Int. 2017; 2017: 1262108.

Ten to twenty percent of patients with total knee arthroplasty (TKA) are dissatisfied with their clinical outcome. Aim of this study was to investigate the impact of personality traits on the subjective outcome of TKA. We investigated 80 patients with 86 computer navigated TKAs. We asked for patients satisfaction and divided patients into two groups (satisfied or dissatisfied). 12 personality traits were tested by the Freiburg Personality Inventory (FPI-R). Postoperative examination included Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and the Visual Analogue Scale (VAS). Radiologic investigation was done in all patients. 84% of our patients were satisfied, while 16% were not satisfied. The FPI-R showed statistical significant influence of four personality traits on patient satisfaction: life satisfaction (p = 0.006), performance orientation (p = 0.015), somatic distress (p = 0.001), and emotional stability (p = 0.002). All clinical scores (VAS, WOMAC, and KSS) showed significantly better results in the satisfied patient. Radiological examination showed optimal alignment of all TKAs. There were no complications requiring revision surgery. The results of our study show that personality traits may influence patients satisfaction and clinical outcome after TKA. Therefore patients personality traits may be a useful predictive factor for postoperative satisfaction after TKA.

Feng-Chih Kuo, 1 Bradley Chen, 2 Mel S. Lee, 1 Shih-Hsiang Yen, 1 and Jun-Wen Wang 1 , *
Knee

The use of modern surgical dressings to prevent wound complications and surgical site infection (SSI) after minimally invasive total knee arthroplasty (MIS-TKA) is lacking. In a prospective, randomized, controlled study, 240 patients were randomized to receive either AQUACEL Ag Surgical dressing (study group) or a standard dressing (control group) after MIS-TKA. The primary outcome was wound complication (SSI and blister). The secondary outcomes were wear time and number of dressing changes in the hospital and patient satisfaction (pain, comfort, and ease of use). In the intention-to-treat analysis, there was a significant reduction in the incidence of superficial SSI (0.8%, 95% CI∶ 0.00–2.48) in the study group compared to 8.3% (95% CI∶ 3.32–13.3) in the control group (p = 0.01). There were no differences in blister and deep/organ-space SSIs between the two groups. Multivariate analysis revealed that AQUACEL Ag Surgical dressing was an independent risk factor for reduction of SSI (odds ratio: 0.07, 95% CI: 0.01–0.58, p = 0.01). The study group had longer wear time (5.2 ± 0.7 versus 1.7 ± 0.4 days, p < 0.0001) and lower number of dressing changes (1.0 ± 0.2 versus 3.6 ± 1.3 times, p < 0.0001). Increased patient satisfaction (p < 0.0001) was also noted in the study group. AQUACEL Ag Surgical dressing is an ideal dressing to provide wound care efficacy, patient satisfaction, reduction of SSI, and cost-effectiveness following MIS-TKA.


Link to article