The Journal of Arthroplasty, Volume 32, Issue 12, 3698 - 3703

Revision Total Hip Arthroplasty With a Monoblock Splined Tapered Grit-Blasted Titanium Stem

Hellman, Michael D. et al.
Hip

Background

In revision total hip arthroplasty (THA), proximal femoral bone loss creates a challenge of achieving adequate stem fixation. The purpose of this study was to examine the outcomes of a monoblock, splined, tapered femoral stem in revision THA.

Methods

Outcomes of revision THA using a nonmodular, splined, tapered femoral stem from a single surgeon were reviewed. With a minimum of 2-year follow-up, there were 68 cases (67 patients). Paprosky classification was 3A or greater in 85% of the cases. Preoperative and postoperative Harris Hip Scores (HHS), radiographic subsidence and osseointegration, limb length discrepancy, complications, and reoperations were analyzed.

Results

The Harris Hip Score improved from 37.4 ± SD 19.4 preoperatively to 64.6 ± SD 21.8 at final follow-up (P < .001). There were 16 revision procedures—8 for septic indications and 8 for aseptic indications. Subsidence occurred at a rate of 3.0% and dislocation at 7.4%. Limb length discrepancy of more than 1 cm after revision was noted in 13.6% of patients. Bone ingrowth was observed in all but 4 patients (94.1%). At 4-year follow-up, Kaplan-Meier estimated survival was 72.9% (95% confidence interval [CI] 57.0-83.8) for all causes of revision, 86.6% (95% CI 72.0-93.9) for all aseptic revision, and 95.5% (95% CI 86.8-98.5) for aseptic femoral revision.

Conclusion

Although complications were significant, revision for femoral aseptic loosening occurred in only 3 patients. Given the ability of this monoblock splined tapered stem to adequately provide fixation during complex revision THA, it remains a viable option in the setting of substantial femoral bone defects.


Link to article