The Journal of Arthroplasty, Volume 29, Issue 7, 1478 - 1481

Modern Retrograde Intramedullary Nails Versus Periarticular Locked Plates for Supracondylar Femur Fractures After Total Knee Arthroplasty

Meneghini, R. Michael et al.
Knee

This study purpose is to analyze outcomes of modern intramedullary (IM) nails with a locked distal screw versus periarticular locking plates for peri-prosthetic supracondylar femur fractures in TKA. Ninety-five consecutive fractures in 91 patients were retrospectively reviewed. Fixation included 29 knees with a retrograde IM nail and 66 periarticular locked plates. Six patients died and 4 were lost to follow-up. There were 2 (9%) nonunions in the IM nail group and 12 non-unions/delayed-unions (19%) in the locked plate group (P = 0.34). A mean of 5.0 distal screws was used in locked plates versus 3.8 distal screws in the IM nails (P < 0.001). Despite a greater quantity of screws in the distal fragment, the failure rate of locked plating was twice that of IM nail fixation.


Link to article