Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25: 798–803, 2007

Joint area constraint had no influence on bone loss in proximal tibia 5 years after total knee replacement

Tuuli Saari Johan Uvehammer Lons Carlsson Lons Regnér Johan Kärrholm
Knee

After total knee replacement (TKR) the bone mineral density (BMD) decreases in the proximal tibia. Our aim was to evaluate if changes in constraint of the cemented AMK TKR (DePuy, Johnson & Johnson, Leeds, UK) had any effect on postoperative bone remodeling in the proximal tibia. We used dual‐energy X‐ray absorptiometry in 43–53 knees to record changes in BMD in three regions of interest around the tibial component up to 5 years after operation with the AMK (DePuy) TKR. The knees had been randomly allocated to receive a flat or a concave tibial insert with retention of the posterior cruciate ligament when preoperative deformity was less severe, and either a concave or a posterior‐stabilized (PS) insert with resection of the posterior cruciate ligament when deformity was more pronounced. All designs were associated with loss of BMD in the proximal tibia. The mean bone loss varied from 5 to 23% depending on the region of interest. There were no statistically significant differences between the groups, and the alteration of tibial insert constraint did not influence the bone remodeling. However, low precision values may have impaired the detection of differences.


Link to article