The Journal of Arthroplasty, ISSN: 0883-5403, Vol: 20, Issue: 8, Page: 998-1001

Isolated Revision of Failed Metal-Backed Patellar Components: Outcome With Minimum 4-Year Follow-Up

W. Vincent Burke; Deborah J. Ammeen; Gerard A. Engh
Knee

Several reports document high failure rates of metal-backed patellar components, but few report the outcome of revising these components to all-polyethylene, cemented implants. At a mean 87.2-month follow-up, we describe a series of 36 patients (40 knees) who underwent isolated metal-backed patellar revision to a cemented, all-polyethylene patellar component. After the patellar revision, 5 patients (6 knees) underwent additional surgery, but no patellar components required revision. The additional surgeries were performed at an average of 77.6 months after patellar revision and included 3 tibial insert exchanges for polyethylene wear, 2 revisions of femoral and tibial components for osteolysis, and 1 realignment procedure for recurrent subluxation of the patella. We conclude that revision of a failed metal-backed patellar component to a cemented, all-polyethylene patella is a durable, successful procedure.


Link to article