Is Intraoperative Use of QuikClot Combat Gauze Effective for Hemostasis after Total Knee Arthroplasty?
Jung Ho Noh, MD,corresponding author Jae Woo Lee, MD, Young Joon Nam, MD, and Ki Yong Choi, MDKnee
Background
To assess the hemostatic effect of QuikClot Combat Gauze (QCG) compared to that of standard gauze during cruciate-retaining total knee arthroplasty (TKA).
Methods
Sixty knees underwent TKA using a pneumatic tourniquet in this prospective randomized study. After implantation of the femoral and tibial components and hardening of the bone cement, the tourniquet was deflated and QCG (group 1) or standard gauze (group 2) was packed into the joint cavity for 5 minutes for hemostasis. Perioperative bleeding volume and blood transfusion volume were compared between two groups.
Results
The mean intraoperative bleeding volume was 64.7 ± 12.7 mL in group 1 and 63.9 ± 9.2 mL in group 2 (p = 0.808). The mean postoperative blood drainage was 349.0 ± 170.6 mL in group 1 and 270.1 ± 136.3 mL in group 2 (p = 0.057). The average postoperative blood transfusion volume was 323.7 ± 325.9 mL in group 1 and 403.6 ± 274.8 mL in group 2 (p = 0.314).
Conclusions
QCG was not significantly effective for reducing perioperative bleeding volume or the blood transfusion rate compared with standard gauze during TKA.