Clinical Orthopaedics and Related Research: August 2003 - Volume 413 - Issue - p 222-232

In Vivo Three-Dimensional Patellar Tracking on the Femur

Asano, Taiyo MD*,**; Akagi, Masao MD†; Koike, Kazuhiro MD*; Nakamura, Takashi MD*
Knee

In vivo three-dimensional patellar tracking under weightbearing conditions was investigated with the principal reference axes of the femur in the coronal and axial planes, using a biplanar image-matching technique. Three-dimensional knee models of eight healthy volunteers were constructed using computed tomography scanning. Projection images of the models were fitted onto anteroposterior and lateral radiographs of the knees at hyperextension and at every 15° from 0° to 120° flexion. Knee motion then was reconstructed on a computer. Patellar tracking during knee flexion was described simply with a medial jerk shift of 8 mm in early flexion until 30° and a linear tracking with minimal mediolateral translation. The linear tracking portion was located laterally 5 mm from the mediolateral center of the femoral condyles. On average, the direction of this linear tracking was almost perpendicular to the distal condylar line in the coronal plane and perpendicular to the posterior condylar axis in the axial plane. These results help improve the understanding of patellofemoral kinematics and provide useful information for the design and positioning of the prostheses used in total knee arthroplasty.


Link to article