The overall component revision rate, including conversion to THA, revision HA, revision with open reduction internal fixation, and Girdlestone procedure, was 5.6% (39/686). Seventeen patients (2.5%) were converted from HA to THA at an average of 1.9 years after index procedure. A significantly lower conversion rate of 1.4% (7/499 patients) was found in the older patient cohort (≥75 years old) compared to 5.3% (11/187) in the younger cohort. The most common causes for conversion surgery to THA were acetabular wear (5 patients), aseptic loosening (4 patients), and periprosthetic fracture (3 patients). There was a significantly lower rate of periprosthetic fracture (0.4% vs 2.5%, P value .025) in the cemented implant group compared to the cementless group. We observed a higher rate of dislocations in the bipolar vs unipolar group (3.8% vs 1%, P value .02) and no other significant differences between these groups.