Clinical Orthopaedics and Related Research: January 2010 - Volume 468 - Issue 1 - p 102–107 doi: 10.1007/s11999-009-1112-3 SYMPOSIUM: PAPERS PRESENTED AT THE ANNUAL MEETINGS OF THE KNEE SOCIETY

Gap Balancing versus Measured Resection Technique for Total Knee Arthroplasty

Dennis, Douglas, A., MD1, 2, 3, 4, a; Komistek, Richard, D., PhD1; Kim, Raymond, H., MD3; Sharma, Adrija, PhD1
Knee

Multiple differing surgical techniques are currently utilized to perform total knee arthroplasty (TKA). We compared knee arthroplasties performed using either a measured resection or gap balancing technique to determine if either operative technique provides superior coronal plane stability as measured by assessment of the incidence and magnitude of femoral condylar lift-off. We performed 40 TKA using a measured resection technique (20 PCL-retaining and 20 PCL-substituting) and 20 PCL-substituting TKA were implanted using gap balancing. All subjects were analyzed fluoroscopically while performing a deep knee bend. The incidence of coronal instability (femoral condylar lift-off) was then determined using a 3-D model fitting technique. The incidence of lift-off greater than 0.75 mm was 80% (maximum, 2.9 mm) and 70% (maximum, 2.5 mm) for the PCL-retaining and substituting TKA groups performed using measured resection versus 35% (maximum, 0.88 mm) for the gap-balanced group. Lift-off greater than 1 mm occurred in 60% and 45% of the PCL-retaining and -substituting TKA using measured resection versus none in the gap-balanced group. Rotation of the femoral component using a gap balancing technique resulted in better coronal stability which we suggest will improve functional performance and reduce polyethylene wear.


Link to article