Geriatr Orthop Surg Rehabil. 2021; 12: 21514593211059865.

Complications and Intraoperative Fractures in Reverse Shoulder Arthroplasty: A Systematic Review

Andrea Dolci, MD,1 Barbara Melis, MD,2 Marco Verona, MD,1 Antonio Capone, PhD,1 and Giuseppe Marongiu, MD1
Shoulder

Introduction

The reverse shoulder arthroplasty is nowadays a treatment option for a variety of shoulder problems. As its incidence rose, also the number of complications increased, including intraoperative fractures.

Significance

We performed a systematic review and critical analysis of the current literature following the PRISMA guidelines. Our purpose was to: 1) determine incidence, causes, and characteristics of intraoperative fractures; 2) evaluate their current treatment options, possible related complications, reoperation rates, and the patients’ outcome; and 3) determine the overall incidence of each complication related to reverse shoulder arthroplasty. The articles were selected from PubMed medical database in April 2020 using a comprehensive search strategy. Rayyan software was used to support the selection process of the records. A descriptive and critical analysis of the results was performed.

Results

The study group included a total of 13,513 reverse shoulder arthroplasty procedures. The total number of complications was 1647 (rate 12.1%). The most common complication was dislocation (340 cases, rate 2.5%). Forty-six studies reported a total of 188 intraoperative fractures among the complications (rate 1.4%). The intraoperative fracture rate was 2.9% and 13.6% in primary and revision settings, respectively. There were 136 humeral fractures, 60% of them occurred in revision RSAs, during the removal of the previous implant, and involved the shaft in the majority of cases (39%). Glenoid fractures were 51 and occurred mostly during the reaming of the glenoid. We observed 7 further related complications (rate of 4%) and 3 reoperations (rate of 1.5%). The outcome was satisfactory in the majority of cases.

Conclusions

A comprehensive review on intraoperative fractures in reverse shoulder arthroplasties is presented. Results suggest favorable outcomes for all treatment methods, with a modest further complication rate. This investigation may aid in the treatment decision-making for these complications.

Keywords: reverse shoulder arthroplasty, complication, intraoperative fracture, periprosthetic fracture, reverse shoulder replacement, systematic review

Link to article