The Journal of Arthroplasty, Volume 35, Issue 6, 1662 - 1666

Clinical Outcomes and Midterm Survivorship of an Uncemented Primary Total Hip Arthroplasty System

Chaudhry, Harman et al.
Hip

Background

The rise in total hip arthroplasty (THA) has led to a concomitant increase in revision THAs. Tracking implant performance therefore remains a significant element of scientific inquiry to garner and maintain public trust in this procedure. There are few available reports of outcomes of a single manufacturer’s total hip system outside registry data.

Methods

We performed a retrospective review of a prospectively generated database to evaluate outcomes of a single manufacturer’s femoral stem and acetabular shell for THA. We report the functional outcomes, revision data, and survivorship for this total hip system.

Results

A total of 1942 primary THAs were implanted into 1672 patients. There were of 57 revisions. There were no cases of acetabular failure at 10-year follow-up. All functional outcome scores demonstrated significant improvements following THA. Kaplan-Meier survival analysis for all-cause revisions demonstrated 2-year implant survival of 97.6% (95% confidence interval [CI], 96.9-98.3), 5-year implant survival of 97.3% (95% CI, 96.5-98.1), and 10-year implant survival of 97.0% (95% CI, 96.0-98.0). When infection was excluded, implant survivorship improved to 99.2% (95% CI, 98.8-99.6) at 2 years, 98.9% (95% CI, 98.5-99.4) at 5 years, and 98.7% (95% CI, 98.1-99.4) at 10 years.

Conclusion

This THA implant system comprising an uncemented press-fit acetabulum used alongside a triple-tapered femoral stem is an excellent option for THA. Implant survivorship at 2, 5, and 10 years is among the best reported for any total hip system in the world.

Link to article