The Journal of Arthroplasty, Volume 32, Issue 12, 3777 - 3781

Are Trends in Total Hip Arthroplasty Bearing Surface Continuing to Change? 2007-2015 Usage in a Large Database Cohort

Bedard, Nicholas A. et al.
Hip

Background

Bearing surface issues related to trunnionosis or metal-on-metal (MoM) articulations have likely impacted recent trends in bearing surface choice. The purpose of this study is to evaluate trends in total hip arthroplasty (THA) bearing surface use, including 2015 data, with respect to the date of operation and patient demographics.

Methods

The Humana dataset was reviewed from 2007 through 2015 to analyze bearing surface usage in primary THA. Four bearing surface types were identified by International Classification of Disease, 10th Revision codes and trended throughout the years: metal-on-polyethylene (MoP), ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), and MoM. Prevalence was analyzed as a function of age and sex.

Results

Of the 28,504 primary THA procedures, the most commonly used bearing was MoP (46.1%), followed by CoP (33.2%), MoM (17.1%), and ceramic-on-ceramic (3.6%). The use of CoP bearings significantly increased from 6.4% in 2007 to 52.0% in 2015, while MoM bearings decreased during this period. MoP bearings decreased over 2012-2015 (P < .001). CoP usage decreased with age, while MoP bearings increased with a transition occurring at 65-69 years of age. Women were more likely to receive MoP bearings (odds ratio [OR] 1.2), while men were more likely to receive MoM and CoP bearings (OR 1.1). Multivariate logistic regression showed age to be an independent predictor of bearing surface choice with patients 65 and older more likely to receive MoP bearings (OR 3.2).

Conclusion

Bearing surface choice in primary THA has changed tremendously from 2007 to 2015. MoM bearing use has decreased as a result of adverse effects. Age continues to remain a significant factor in bearing surface choice.


Link to article