The Journal of Arthroplasty, Volume 35, Issue 8, 2155 - 2160

Wagner Cone Midterm Survivorship and Outcomes

Gholson, J. Joseph et al.
Hip

Background

Total hip arthroplasty (THA) in patients with abnormal proximal femoral anatomy requires an individualized treatment approach to prevent complications. Metaphyseal engaging stems in this population risk fracture, size/offset mismatch, and aseptic loosening. The Wagner conical femoral implant is a short diaphyseal engaging femoral stem that could improve treatment success in this difficult patient population.

Methods

We identified 302 consecutive patients undergoing THA using the Wagner cone femoral prosthesis between January 2010 and January 2017. Clinical, radiographic, and patient-reported outcomes were obtained through chart review and radiographic measurements of postoperative X-rays. We used multivariate analysis to determine predictors of poor outcomes. Kaplan-Meier curves were created to demonstrate implant survivorship with reoperation and revision as endpoints. The average follow-up was 3.2 years, with a minimum of 2 years.

Results

The implant retention survival rate during the 3.2-year study period was 98.7%. The overall reoperation rate was 4.2%, with infection followed by fracture being the most common reasons for reoperation. No patients were revised for aseptic loosening, and no patients were revised for subsidence. The average subsidence was 1.1 mm. The Harris Hip Score improved from 48.6 ± 7.3 (range, 28-64) preoperatively to 86.1 ± 8.5 (range, 66-100) at latest follow-up. The patient-reported satisfaction rate was 98.3%.

Conclusion

The Wagner cone femoral prosthesis demonstrated excellent clinical, radiographic, and patient-reported functional outcomes at midterm follow-up. We recommend use of the Wagner cone in THA patients with challenging proximal femoral anatomy, small femoral diameter, or poor metaphyseal bone quality.

Link to article