This study investigated the relationships between the preoperative femoral anteversions and the femoral stem anteversion using CT scans and CT-based 3D models to determine whether any preoperative anteversion measurement correlates with the postoperative stem anteversion. Pre-operative and post-operative CT scans of 19 hips with THAs were evaluated. Five preoperative anatomical femoral anteversion measurements (CT-Head, CT-Below Head, CT-Neck, 3D-Head, and 3D-Neck) were compared with the postoperative femoral stem anteversion. The preoperative CT-Neck anteversion measurement was most correlated with the postoperative stem anteversion (r = 0.761, P = 0.002) with the narrowest ranges of the differences (−10.2° to 11.0°). The preoperative anteversions using the femoral neck geometry from CT scans can be used for the estimation of the postoperative femoral stem anteversion in THA.