The Knee, ISSN: 0968-0160, Vol: 7, Issue: 3, Page: 165-170
Knee
Link to article
Treatment of supracondylar femoral fracture above total knee replacement by custom made hinged prosthesis
J. Keenan; G. Chakrabarty; J. H. NewmanKnee
A supracondylar fracture above a total knee arthroplasty (TKA) is a devastating complication for both the patient and surgeon. Various methods of treatment are available. We have treated seven cases of displaced supracondylar fractures above a total knee replacement with custom made implants. This technique allows rapid post-operative recovery and gives a good functional outcome.