We compared the sterile elastic exsanguination tourniquet and the pneumatic tourniquet for total knee arthroplasty. 145 patients were operated on using a pneumatic tourniquet and 166 with the sterile elastic exsanguination tourniquet. Patients with the sterile elastic exsanguination tourniquet had a smaller decrease in hemoglobin on post-operative days one (P < 0.028) and three (P < 0.045). The amount of blood collected from drains at 24 h was significantly lower in the sterile elastic exsanguination group. A trend towards a higher rate of wound complications within 3 months following the operation was found in the pneumatic tourniquet group. The sterile elastic exsanguination tourniquet works at least as good as the pneumatic one.
CoxaPro
> Clinical Library > Tervetuloa Clinical Libraryyn > The Sterile Elastic Exsanguination Tourniquet vs. the Pneumatic Tourniquet for Total Knee Arthroplasty
The Journal of Arthroplasty, Volume 30, Issue 4, 595 - 599
Knee
The Sterile Elastic Exsanguination Tourniquet vs. the Pneumatic Tourniquet for Total Knee Arthroplasty
Brin, Yaron S. et al.Knee