Both of the groups were comparable in terms of age, sex, body mass index, and pre-operative Hb. There was a significant difference between the EACA group and control group in terms of intraoperative blood loss (150 ml vs. 165 ml, P = 0.01), drain output (494 ml vs. 1062 ml, P < 0.001), postoperative Hb (9.9 g/dl vs. 8.6 g/dl, P = 0.002), drop in Hb (2.2 g/dl vs. 3.1 g/dl, P = 0.026) and transfusion rate (median transfusion 0 vs. 1, P < 0.001). The total blood loss, as calculated by the Hb balance method, was significantly less (P < 0.001) in the EACA group (0.99 l) compared with the control group (2.71 l). None of the patients developed any adverse reaction/complication to the drug.