Arch Orthop Trauma Surg 131, 1477–1480 (2011).

Rotational alignment in total knee arthroplasty: intraoperative inter- and intraobserver reliability of Whiteside’s line

Vanin, N., Panzica, M., Dikos, G. et al.
Knee

Introduction

Proper rotational alignment is a critical step of total knee arthroplasty. For intraoperative determination of femoral rotation, Whiteside suggests a perpendicular line to the axis of the center of the trochlea and the intercondylar notch (Whiteside’s line).

Method

In a prospective clinical study, the intraoperative position of Whiteside’s line was measured in 30 patients with the help of a navigation system.

Results

Whiteside’s line was 2.1° ± 1.5° externally rotated compared to a navigation based computer calculated preliminary AP axis of the femur. The intraobserver-reliability after 3 repeated measurements each was 1.6° for the senior surgeon and 1.4° for the junior surgeon (p = 0.598, p = 0.968). The interobserver reliability between the measurements by the senior and junior surgeon was 1.4° (p = 0.547).

Conclusion

Navigated intraoperative measurements of Whiteside’s line showed a high inter- and intraobserver reliability. Considering the variability between Whiteside’s line and the transepicondylar axis, intraoperative assessment of both the methods is recommended.


Link to article