Trials. 2020; 21: 721.

Robotic-arm assisted medial unicondylar knee arthroplasty versus jig-based unicompartmental knee arthroplasty with navigation control: study protocol for a prospective randomised controlled trial

Babar Kayani, Sujith Konan, Jenni Tahmassebi, Atif Ayuob, Peter D. Moriarty, and Fares S. Haddad
Knee

Background

There remains a paucity of clinical studies assessing how any differences in accuracy of implant positioning between robotic-arm assisted unicompartmental knee arthroplasty (RO UKA) and conventional jig-based unicompartmental knee arthroplasty (CO UKA) translate to patient satisfaction, functional outcomes, and implant survivorship. The objectives of this study are to compare accuracy of implant positioning, limb alignment, patient satisfaction, functional outcomes, implant survivorship, cost-effectiveness, and complications in CO UKA versus RO UKA. Computer navigation will be used to assess intraoperative knee kinematics in all patients undergoing CO UKA.

Methods and analysis

This prospective randomised controlled trial will include 140 patients with symptomatic medial compartment knee arthritis undergoing primary UKA. Following informed consent, patients will be randomised to CO UKA (control group) or RO UKA (investigation group) at a ratio of 1:1 using an online random number generator. The primary objective of this study is to compare accuracy of implant positioning in CO UKA versus RO UKA. The secondary objectives are to compare the following outcomes between the two treatment groups: limb alignment, surgical efficiency, postoperative functional rehabilitation, functional outcomes, quality of life, range of motion, resource use, cost effectivness, and complications. Observers will review patients at regular intervals for 2 years after surgery to record predefined study outcomes pertaining to these objectives. Ethical approval was obtained from the London-Bloomsbury Research Ethics Committee, UK. The study is sponsored by University College London, UK.

Discussion

This study compares a comprehensive and robust range of clinical, functional, and radiological outcomes in CO UKA versus RO UKA. The findings of this study will provide an improved understanding of the differences in CO UKA versus RO UKA with respect to accuracy of implant positioning, patient satisfaction, functional outcomes, implant survivorship, cost-effectiveness, and complications.

Trial registration

ClinicalTrials.gov NCT04095637. Registered on 19 September 2019.