Results of stemless shoulder arthroplasty: a systematic review and meta-analysis

Joost I.P. Willems, Jim Hoffmann, Inger N. Sierevelt, Michel P.J. van den Bekerom, Tjarco D.W. Alta, and Arthur van Noort
Shoulder
  • Stemless shoulder arthroplasty relies solely on cementless metaphyseal fixation and is designed to avoid stem-related problem such as intraoperative fractures, loosening, stress shielding or stress-risers for periprosthetic fractures.

  • Many designs are currently on the market, although only six anatomic and two reverse arthroplasty designs have results published with a minimum of two-year follow-up.

  • Compared to stemmed designs, clinical outcome is equally good using stemless designs in the short and medium-term follow-up, which is also the case for overall complication and revision rates.

  • Intraoperative fracture rate is lower in stemless compared to stemmed designs, most likely due to the absence of intramedullary preparation and of the implantation of a stem.

  • Radiologic abnormalities around the humeral implant are less frequent compared to stemmed implants, possibly related to the closer resemblance to native anatomy.

  • Between stemless implants, several significant differences were found in terms of clinical outcome, complication and revision rates, although the level of evidence is low with high study heterogeneity; therefore, firm conclusions could not be drawn.

  • There is a need for well-designed long-term randomized trials with sufficient power in order to assess the superiority of stemless over conventional arthroplasty, and of one design over another.