Clinical Orthopaedics and Related Research: November 2003 - Volume 416 - Issue - p 84-92

Patellar Options in Revision Total Knee Arthroplasty

Rorabeck, Cecil H. MD, FRCSC*; Mehin, Ramin MD, FRCSC*; Barrack, Robert L. MD**
Knee

There are numerous options that need to be considered by the surgeon at the time of revision total knee arthroplasty (TKA). One needs to consider the reason for the revision, the type of patella in place, and the length of time the patella has been in place. The surgeon also needs to consider the status of the patellar bone stock, the stability of the patellar component (well-fixed or loose), and the component type (cemented or metal-backed). Assuming that the existing prosthesis is not metal-backed and has minimal PE wear, then it is preferable to retain a well-fixed all-PE cemented patellar button. However, if the button is metal-backed, then it probably is best to remove the button and replace it with an all-PE domed patellar component. Assuming more than 8 mm of patellar bone stock is remaining, it usually is best to cement an all-PE dome-shaped patella. However, if less than 8 mm is remaining, then that patient can be left with a patelloplasty, recognizing that this individual is going to continue with a high likelihood of anterior knee pain, subluxation, and poor functional results. In that situation, it may be preferable to consider a bone stock augmentation.


Link to article