Otsikko Julkaisija Vuosi Info
Midflexion instability in total knee arthroplasty: a systematic review Longo, U.G., Candela, V., Pirato, F. et al. 2021 Midflexion instability in total knee arthroplasty: a systematic review. Knee Surg Sports Traumatol Arthrosc 29, 370–380 (2021). Open
Threshold values for stress radiographs in unstable knees after total knee arthroplasty Murer, M., Falkowski, A.L., Hirschmann, A. et al. 2021 Threshold values for stress radiographs in unstable knees after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 29, 422–428 (2021). Open
A cruciate-retaining implant can treat both knees of most windswept deformities when performed with calipered kinematically aligned TKA Howell, S.M., Shelton, T.J., Gill, M. et al. 2021 A cruciate-retaining implant can treat both knees of most windswept deformities when performed with calipered kinematically aligned TKA. Knee Surg Sports Traumatol Arthrosc 29, 437–445 (2021). Open
Influence of component design on in vivo tibiofemoral contact patterns during kneeling after total knee arthroplasty: a systematic review and meta-analysis Lynch, J.T., Scarvell, J.M., Galvin, C.R. et al. 2021 Influence of component design on in vivo tibiofemoral contact patterns during kneeling after total knee arthroplasty: a systematic review and meta-analysis. Knee Surg Sports Traumatol Arthrosc 29, 446–466 (2021). Open
Mid-flexion stability in the anteroposterior plane is achieved with a medial congruent insert in cruciate-retaining total knee arthroplasty for varus osteoarthritis Tsubosaka, M., Ishida, K., Kodato, K. et al. 2021 Mid-flexion stability in the anteroposterior plane is achieved with a medial congruent insert in cruciate-retaining total knee arthroplasty for varus osteoarthritis. Knee Surg Sports Traumatol Arthrosc 29, 467–473 (2021). Open
Osteoarthritic knees have a highly variable patellofemoral alignment: a systematic review Hochreiter, B., Moser, L.B., Hess, S. et al. 2021 Osteoarthritic knees have a highly variable patellofemoral alignment: a systematic review. Knee Surg Sports Traumatol Arthrosc 29, 483–490 (2021). Open
In vivo femorotibial kinematics of medial-stabilized total knee arthroplasty correlates to post-operative clinical outcomes Alesi, D., Marcheggiani Muccioli, G., Roberti di Sarsina, T. et al. 2021 In vivo femorotibial kinematics of medial-stabilized total knee arthroplasty correlates to post-operative clinical outcomes. Knee Surg Sports Traumatol Arthrosc 29, 491–497 (2021). Open
Surgeon-defined assessment is a poor predictor of knee balance in total knee arthroplasty: a prospective, multicenter study MacDessi, S.J., Wood, J.A., Diwan, A.D. et al. 2021 Surgeon-defined assessment is a poor predictor of knee balance in total knee arthroplasty: a prospective, multicenter study. Knee Surg Sports Traumatol Arthrosc 29, 498–506 (2021). Open
Topical co-delivery of platelet rich fibrin and tranexamic acid does not decrease blood loss in primary total knee arthroplasty compared to the standard of care: a prospective, randomized, controlled trial Tandogan, R.N., Polat, M., Beyzadeoglu, T. et al. 2021 Topical co-delivery of platelet rich fibrin and tranexamic acid does not decrease blood loss in primary total knee arthroplasty compared to the standard of care: a prospective, randomized, controlled trial. Knee Surg Sports Traumatol Arthrosc 29, 519–528 (2021). Open
Three distinct recovery patterns following primary total knee arthroplasty: dutch arthroplasty register study of 809 patients van Egmond, J.C., Hesseling, B., Melles, M. et al. 2021 Three distinct recovery patterns following primary total knee arthroplasty: dutch arthroplasty register study of 809 patients. Knee Surg Sports Traumatol Arthrosc 29, 529–539 (2021). Open
Patellar component size effects patellar tilt in total knee arthroplasty with patellar resurfacing Joseph, L., Batailler, C., Roger, J. et al. 2021 Patellar component size effects patellar tilt in total knee arthroplasty with patellar resurfacing. Knee Surg Sports Traumatol Arthrosc 29, 553–562 (2021). Open
High intra- and inter-observer reliability of planning implant size in MRI-based patient-specific instrumentation for total knee arthroplasty Schoenmakers, D.A.L., Theeuwen, D.M.J., Schotanus, M.G.M. et al. 2021 High intra- and inter-observer reliability of planning implant size in MRI-based patient-specific instrumentation for total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 29, 573–578 (2021). Open
Factors predicting repeat revision and outcome after aseptic revision total knee arthroplasty: results from the New Zealand Joint Registry Klasan, A., Magill, P., Frampton, C. et al. 2021 Factors predicting repeat revision and outcome after aseptic revision total knee arthroplasty: results from the New Zealand Joint Registry. Knee Surg Sports Traumatol Arthrosc 29, 579–585 (2021). Open
Improving radiographic patello-femoral tracking in total knee arthroplasty with the use of a flexion spacer: a case–control study D’Elicio, D.G., Attanasio, M., Ruffo, G. et al. 2021 Improving radiographic patello-femoral tracking in total knee arthroplasty with the use of a flexion spacer: a case–control study. Knee Surg Sports Traumatol Arthrosc 29, 586–593 (2021). Open
Ten-year survival rate of 89% after distal femoral osteotomy surgery for lateral compartment osteoarthritis of the knee Shivji, F.S., Foster, A., Risebury, M.J. et al. 2021 Ten-year survival rate of 89% after distal femoral osteotomy surgery for lateral compartment osteoarthritis of the knee. Knee Surg Sports Traumatol Arthrosc 29, 594–599 (2021). Open
The KOOS-12 shortform shows no ceiling effect, good responsiveness and construct validity compared to standard outcome measures after total knee arthroplasty Eckhard, L., Munir, S., Wood, D. et al. 2021 The KOOS-12 shortform shows no ceiling effect, good responsiveness and construct validity compared to standard outcome measures after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 29, 608–615 (2021). Open
Additional periarticular catheter shows no superiority over single-shot local infiltration analgesia alone in unicondylar knee replacement Meier, M., Burkhardt, P., Huth, J. et al. 2021 Additional periarticular catheter shows no superiority over single-shot local infiltration analgesia alone in unicondylar knee replacement. Knee Surg Sports Traumatol Arthrosc 29, 627–632 (2021). Open
The tibial cut in total knee arthroplasty influences the varus alignment, the femoral roll-back and the tibiofemoral rotation in patients with constitutional varus Faschingbauer, M., Hacker, S., Seitz, A. et al. 2021 The tibial cut in total knee arthroplasty influences the varus alignment, the femoral roll-back and the tibiofemoral rotation in patients with constitutional varus. Knee Surg Sports Traumatol Arthrosc 29, 641–651 (2021). Open
Varus inclination of the tibia is related to patellofemoral osteoarthritis in Japanese female patients with moderate knee osteoarthritis Nejima, S., Kumagai, K., Kobayashi, H. et al. 2021 Varus inclination of the tibia is related to patellofemoral osteoarthritis in Japanese female patients with moderate knee osteoarthritis. Knee Surg Sports Traumatol Arthrosc 29, 652–658 (2021). Open
A constrained-condylar fixed-bearing total knee arthroplasty is stabilised by the medial soft tissues Athwal, K.K., Willinger, L., Manning, W. et al. 2021 A constrained-condylar fixed-bearing total knee arthroplasty is stabilised by the medial soft tissues. Knee Surg Sports Traumatol Arthrosc 29, 659–667 (2021). Open
Higher age, female gender, osteoarthritis and blood transfusion protect against periprosthetic joint infection in total hip or knee arthroplasties: a systematic review and meta-analysis Resende, V.A.C., Neto, A.C., Nunes, C. et al. 2021 Higher age, female gender, osteoarthritis and blood transfusion protect against periprosthetic joint infection in total hip or knee arthroplasties: a systematic review and meta-analysis. Knee Surg Sports Traumatol Arthrosc 29, 8–43 (2021). Open
Comparative Efficacy of the Different Surgical Approaches in Total Knee Arthroplasty: A Systematic-Review and Network Meta-Analysis Bouché, Pierre-Alban et al. 2021 The Journal of Arthroplasty, Volume 36, Issue 3, 1187 - 1194.e1 Open
Perioperative Systemic Dexamethasone Reduces Length of Stay in Total Joint Arthroplasty: A Systematic Review and Meta-Analysis of Randomized Controlled Trials Lex, Johnathan R. et al. 2021 The Journal of Arthroplasty, Volume 36, Issue 3, 1168 - 1186 Open
Analysis of Hip and Knee Reconstruction Questions on the Orthopedic In-Training Examination Premkumar, Ajay et al. 2021 The Journal of Arthroplasty, Volume 36, Issue 3, 1156 - 1159 Open
Accuracy of Preoperative Templating in Total Hip Arthroplasty With Special Focus on Stem Morphology: A Randomized Comparison Between Common Digital and Three-Dimensional Planning Using Biplanar Radiographs Brenneis, Marco et al. 2021 The Journal of Arthroplasty, Volume 36, Issue 3, 1149 - 1155 Open