Otsikko Julkaisija Vuosi Info
Osteolytic Indicators Found in Total Knee Arthroplasty Synovial Fluid Aspirates Kovacik, Mark W. BS*; Gradisar, Ivan A. Jr. MD*; Haprian, John J. MT**; Alexander, Thomas S. PhD** 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 186-194 Open
Rotating Hinge Total Knee Arthroplasty in Severely Affected Knees Westrich, Geoffrey H. MD; Mollano, Anthony V. BA; Sculco, Thomas P. MD; Buly, Robert L. MD; Laskin, Richard S. MD; Windsor, Russell MD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 195-208 Open
Geometric Total Knee Replacement: Operative Considerations Riley, Lee Hunter Jr. MD; Peltier, Leonard F. MD, PhD 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 3-8 Open
Articulating Versus Static Spacers in Revision Total Knee Arthroplasty for Sepsis Fehring, Thomas K. MD; Odum, Susan MEd; Calton, Thomas F. MD; Mason, J. Bohannon MD 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 9-16 Open
Ten-to 12-Year Followup of the Insall-Burstein I Total Knee Prosthesis Thadani, Peter J. MD*; Vince, Kelly G. MD**; Ortaaslan, Sevan G. MD*; Blackburn, Dennis C. DO*; Cudiamat, Cecilia V. BS** 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 17-29 Open
Prospective Randomized Clinical Trial of Continuous Passive Motion After Total Knee Arthroplasty MacDonald, Steven J. MD*; Bourne, Robert B. MD*; Rorabeck, Cecil H. MD*; McCalden, Richard W. MD*; Kramer, John PhD**; Vaz, Margaret MSc** 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 30-35 Open
Deep-Dish Congruent Tibial Component Use in Total Knee Arthroplasty: A Randomized Prospective Study Laskin, Richard S. MD*; Maruyama, Yuichiro MD**; Villaneuva, Manuel MD†; Bourne, Robert MD‡ 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 36-44 Open
Functional Medial Ligament Balancing in Total Knee Arthroplasty Whiteside, Leo A. MD; Saeki, Kazuhiko MD, PhD; Mihalko, William M. MD, PhD 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 45-57 Open
Primary Constrained Condylar Knee Arthroplasty for the Arthritic Valgus Knee Easley, Mark E. MD*; Insall, John N. MD**; Scuderi, Giles R. MD**; Bullek, David D. MD† 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 58-64 Open
Athletic Activity After Total Knee Arthroplasty Healy, William L. MD; Iorio, Richard MD; Lemos, Mark J. MD 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 65-71 Open
Rotational Malalignment of the Femoral Component in Total Knee Arthroplasty Fehring, Thomas K. MD 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 72-79 Open
The Role of Bladder Catheterization in Total Knee Arthroplasty Iorio, Richard MD; Healy, William L. MD; Patch, Douglas A. MD; Appleby, David MPH 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 80-84 Open
Total Knee Arthroplasty in Patients 40 Years of Age and Younger With Osteoarthritis Lonner, Jess H. MD*; Hershman, Stuart BA*; Mont, Michael MD**; Lotke, Paul A. MD* 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 85-90 Open
Treatment of Periprosthetic Tibial Fractures Hanssen, Arlen D. MD; Stuart, Michael J. MD 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 91-98 Open
The Cost of Teaching Total Knee Arthroplasty Surgery to Orthopaedic Surgery Residents Lavernia, Carlos J. MD; Sierra, Rafael J. MD; Hernandez, Ruben A. MD 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 99-107 Open
A Randomized Comparison of All-Polyethylene and Metal-Backed Tibial Components Gioe, Terence J. MD***; Bowman, Kevin R. MD† 2000 Clinical Orthopaedics and Related Research: November 2000 - Volume 380 - Issue - p 108-115 Open
Total Hip Arthroplasty Using a Ceramic Prosthesis Sedel, Laurent MD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 3-11 Open
Alternate Bearing Surfaces in Total Joint Arthroplasty: Biologic Considerations Archibeck, Michael J. MD*; Jacobs, Joshua J. MD*; Black, Jonathan PhD** 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 12-21 Open
Ceramic Femoral Head Retrieval Data Willmann, Gerd MS, PhD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 22-28 Open
Ceramic Component Failure and the Role of Proof Testing Pfaff, Hans-Georg; Ing, Dipl 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 29-33 Open
Clinical and Hip Simulator Comparisons of Ceramic-on-Polyethylene and Metal-on-Polyethylene Wear Clarke, Ian C. PhD*; Gustafson, Allen MD** 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 34-40 Open
Modern Ceramic-on-Ceramic Total Hip Systems in the United States: Early Results Garino, Jonathan P. MD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 41-47 Open
Evolution of Alumina-on-Alumina Implants: A Review Sedel, Laurent MD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 48-54 Open
Ceramic Hip Prostheses in Young Patients: A Retrospective Study of 74 Patients Fenollosa, Joaquin MD, PhD; Seminario, Pablo MD; Montijano, Cosme MD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 55-67 Open
As part of a search for better articulation in total hip prostheses, the decrease in the thickness of the socket in different total hip prostheses was measured in vivo. The wear rates of (1) RCH 1000 (molecular weight, 106) socket gammairradiated with 100 Mrad articulating with a crude COP (stainless steel containing 20% cobalt and 0.01% phosphorous) metal femoral head; (2) RCH 1000 socket nonirradiated articulating with a crude COP femoral head; (3) RCH 1000 socket irradiated with 100 Mrad articulating with an alumina femoral head; (4) ultra high molecular weight polyethylene (molecular weight, 5–6 × 106) socket articulating with an alumina femoral head; and (5) ultrahigh molecular weight polyethylene socket articulating with a stainless steel femoral head (T-28) were 0.06, 0.30, 0.06, 0.10 and 0.25 mm/year, respectively, in the authors’ clinical cases. Alumina femoral heads were effective in decreasing wear of the polyethylene socket. However, the wear rates of gamma-irradiated sockets articulating with alumina and with metal femoral heads wear very low and were not different from each other. Regarding the relationship between wear rate and the thickness of the ultra high molecular weight polyethylene socket articulating with a 28 mm alumina femoral head, on radiographs, average wear rates of socket thicknesses of 7, 8, 9, 10 and 11 mm were 0.14, 0.15, 0.12, 0.06, and 0.08 mm/year, respectively. On measuring retrieved prostheses, average wear rates of 7, 8, 9 and 11 mm thickness sockets were 0.2, 0.19, 0.14, and 0.1 mm/year, respectively. The wear of sockets has been proven to be minimal in alumina femoral heads articulating with ultrahigh molecular weight polyethylene sockets thicker than 10 mm. Bizot, Pascal MD; Banallec, Laurence MD; Sedel, Laurent MD; Nizard, Remy MD, PhD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 68-76 Open