Knee Surgery, Sports Traumatology, Arthroscopy November 2018, Volume 26, Issue 11, pp 3438–3443

Native rotational knee kinematics is restored after lateral UKA but not after medial UKA

Wada, K., Hamada, D., Takasago, T. et al.
Knee

Purpose

The aim of this study was to compare the intraoperative kinematics of medial and lateral unicompartmental knee arthroplasty (UKA) with those of the native knee using a navigation system.

 

Methods

Six fresh-frozen cadaveric knees were included in the study. Medial UKA was performed in all right knees and lateral UKA was performed in all left knees. All UKA procedures were performed with a computerised navigation system. The tibial internal rotation angle and coronal alignment of the mechanical axis during passive knee flexion were assessed as rotational and varus/valgus kinematics before and after surgery using the navigation system.

 

Results

The rotation angles of the tibia in the early flexion phase of medial UKA were significantly larger than those of native knees (p = 0.008 at minimum knee flexion, p = 0.008 at 0° knee flexion). The rotational kinematics of lateral UKA was similar to those of the native knees throughout knee flexion. There were no significant differences in varus/valgus kinematics between native and UKA knees.

 

Conclusion

The rotational kinematics of the native knee was not restored after medial UKA but was preserved after lateral UKA. There were no significant differences in the varus/valgus kinematics after either medial or lateral UKA when compared with those of the native knees. Thus, the geometry of the medial tibial articular surface is a determinant of the ability to restore the rotational kinematics of the native knee. Surgeons and implant designers should be aware that the anatomical medial articular geometry is an important factor in restoration of the native knee kinematics after knee arthroplasty.


Link to article