The Journal of Arthroplasty, ISSN: 0883-5403, Vol: 36, Issue: 7, Page: S104-S110

Managing Hip-Spine Concepts in the Direct Anterior Approach With Use of Fluoroscopy

Jeffrey J. Frandsen; Timothy L. Kahn; Lucas A. Anderson; Christopher E. Pelt; Christopher L. Peters; Jeremy M. Gililland
Hip

Background

The spinopelvic relationship in regard to total hip arthroplasty has become a topic of increasing interest in recent years. Hip arthritis and a stiff lumbar spine create a situation where the spinopelvic junction has decreased mobility, which in turn increases the risk of instability after total hip arthroplasty as the femoral acetabular joint must undergo increased motion. Regardless of the approach, surgeons should be aware of the risk of instability in patients with a stiff spinopelvic junction and the necessary modifications to component positioning to avoid postoperative instability. As many direct anterior approach surgeons use fluoroscopy for intraoperative navigation, anterior approach surgeons must also understand how to best use this technology to improve component positioning.

Methods

In this article, we address the basic concepts surrounding spinopelvic stiffness, the intraoperative component adjustments necessary for optimizing stability, and how to appropriately use fluoroscopy for navigation in the direct anterior approach.

Conclusions

Appropriate use of intraoperative fluoroscopy includes understanding the impact of parallax and distortion, properly recreating the patient’s standing functional pelvic plane intraoperatively and adjusting the cup’s target position based on a preoperative understanding of the patient’s spinopelvic motion.

Link to article