J Orthop Surg Res 9, 36 (2014).

Is fibrin sealant effective and safe in total knee arthroplasty? A meta-analysis of randomized trials

Wang, H., Shan, L., Zeng, H. et al.
Knee

The objective of this study was to evaluate the efficacy and safety of fibrin sealant in patients following total knee arthroplasty (TKA). A comprehensive literature search of the electronic databases PubMed, MEDLINE, Web of Science, and Cochrane Library for published randomized controlled trials (RCTs) was undertaken. The evidence base was critically appraised using a tool from the Cochrane Bone, Joint and Muscle Trauma Group. Eight RCTs involving 641 patients were included. The use of fibrin sealant significantly reduced postoperative drainage (weighted mean difference (WMD) −346, 95% confidence interval (CI) −496.29 to −197.54, P < 0.00001) and blood transfusions (risk ratio (RR) 0.47, 95% CI 0.35 to 0.63, P < 0.00001) and led to a significant improvement in the range of motion (WMD 16.59, 95% CI 6.92 to 26.25, P = 0.0008). However, using fibrin sealant did not significantly reduced total blood loss (WMD −305.25, 95% CI −679.44 to 68.95, P = 0.11). Regarding complications, there were no significant differences in any adverse events, fever, infection, or hematoma among the study groups. In conclusion, the present meta-analysis indicates that the use of fibrin sealant was effective and safe as a hemostatic therapy for patients with TKA.


Link to article