Is diaphyseal fixation of short neck-retaining stem prostheses related to the size of the implant?
Pons-Cabrafiga M, Arias de la Torre J, Berlanga-de-Mingo D, Lobo-Escolar L.Hip
Introduction:
Short-stem hip prostheses present variable proximal femoral bone radiological findings. The aims of this study were to analyse, in our patients with implanted collum femoris-preserving (CFP) stems, cancellous bone remodelling, cortical distal hypertrophy and pedestal formation, and the relationship between those radiological changes that suggest distal fixation with the size of the stem.
Methods:
From October 2001 to December 2012 a total of 199 consecutive primary total hip arthroplasties in 180 patients were performed at our department using the CFP stem and followed up for a minimum of 5 years until December 2017.
Results:
Stress shielding was present in 74% of oversized stems cases, but in normal or undersized stems, stress shielding was present in 8.5%. Cortical hyperthrophy was observed in 49% of the oversized stems and in 6% of the normal or undersized ones. Finally, non-statistically significant differences (p = 0.089) in pedestal formation were found, present in 16.3% of the oversized stems and in 6% of normal or undersized ones.
Conclusions:
Oversized stems cause more stress shielding and distal cortical hypertrophy in the distal part of the stem, which indicates distal fixation in bigger sizes of stem.