The Journal of Arthroplasty, Volume 28, Issue 8, 1310 - 1313

Intra-Operative Periprosthetic Fractures Associated With Press Fit Stems in Revision Total Knee Arthroplasty

Cipriano, Cara A. et al.
Knee

The purpose of this study is to report the incidence, management, and outcomes of periprosthetic fractures associated with the insertion of press-fit stems during revision total knee arthroplasty (TKA). Immediate and six week post-operative radiographs from 634 stemmed implants (307 femoral, 327 tibial) from 420 consecutive revision TKAs were reviewed. Sixteen tibial (4.9%) and 3 femoral (1%) fractures (combined incidence 3.0%) were identified. All healed uneventfully without operative intervention, with no evidence of implant loosening at a mean of 23 months (range 12 to 47 months). The technique of tightly press fitting stems into the diaphysis is associated with a small rate (3%) of periprosthetic fractures; most were non or minimally displaced, all healed uneventfully with non-operative management and were not associated with implant loosening.


Link to article