CoxaPro
> Clinical Library > Tervetuloa Clinical Libraryyn > Fracture of a Ceramic Femoral Head After Ceramic-On-Ceramic Total Hip Arthroplasty
The Journal of Arthroplasty, ISSN: 0883-5403, Vol: 21, Issue: 7, Page: 1072-1073
Hip
Link to article
Fracture of a Ceramic Femoral Head After Ceramic-On-Ceramic Total Hip Arthroplasty
Torán, Manuel Malillos; Cuenca, Jorge; Martinez, Angel Antonio; Herrera, Antonio; Thomas, Javier VicenteHip
A case of fracture of the ceramic head of a total hip arthroplasty is presented, which was a total cementless arthroplasty with ceramic-on-ceramic articulation. No history of trauma was observed. The arthroplasty was revised, and a new cementless arthroplasty with a polyethylene insert and a metal head was inserted. The result has been satisfactory.
Link to article