Synovial fluid was collected from 72 patients: 22 (30.6%) proven infections, 22 (30.6%) aseptic implant failures, and 28 (38.8%) controls. Synovial fluid was obtained from the hip in 18 (25%) and knee in 54 (75%) cases. Among infections, there were 16 (22.2%) acute and 6 (8.3%) chronic PJIs. The median (interquartile range) LCN2 concentration in synovial fluid was 1536.5 ng/mL (261.8-12,923) in the infection group, 87.0 (54.8-135) in the aseptic group, and 55 (45-67.8) in the control group (P < .001). LCN2 discriminated nearly perfectly between controls and confirmed infection (area under the receiver operating characteristic 0.98, 95% confidence interval 0.95-1.00). The optimal cut-off value for maximal sensitivity (86.3%) and specificity (77.2%) to discriminate aseptic failure versus proven infection was 152 ng/mL, with an area under the receiver operating characteristic of 0.92 (95% confidence interval 0.84-0.99).