Shoulder Elbow. 2020 Apr; 12(2): 114–123

Delta Xtend reverse shoulder arthroplasty – Results at a minimum of five years

Craig M Ball
Shoulder

Background

Reverse shoulder arthroplasty provides predictable pain relief and improvements in function, but concerns remain regarding complication rates and there is little long-term outcome data. The aim of this study was to review the clinical and radiographic outcomes of the Delta Xtend reverse shoulder arthroplasty at a minimum of five years.

Methods

Ninety-six Delta Xtend reverse shoulder arthroplasty procedures were performed in 93 patients. There were 41 males and 52 females with an average age of 74.9 years. All available patients returned for clinical and radiographic analysis, including completion of patient reported outcome measures.

Results

The complication rate was 9.4%. There were three revisions (3.1%) and two other reoperations (2.1%). Fifty-nine shoulders were available for review at an average of 81 months. Average forward flexion was 142°. Average American Shoulder and Elbow Assessment Score improved from 27.6 to 78.5 (p<0.001). Radiolucent lines and/or proximal bone resorption was seen in 35.4%. Scapula notching was observed in 69.1%, with Grade III or IV notching in 20%. These findings had no effect on patient reported outcome measures.

Discussion

This study confirms the clinical benefits of reverse shoulder arthroplasty, with improvements maintained out to 10 years. The high rate of scapula notching remains a concern. Further study is needed to fully understand the clinical significance of notching, as well as the potential benefits of newer implant designs.

Keywords: shoulder joint replacement, reverse shoulder arthroplasty, complication, scapula notching, patient reported outcome measures

Link to article