Background
Although the popularity of the direct anterior approach for total hip arthroplasty has increased, the femoral procedure in this approach is considered technically challenging, and one of the most frequent complications reported was periprosthetic femoral fractures. The present study aimed to identify factors for predicting the risk of periprosthetic femoral fractures after using stems with a cementless tapered-wedge design through the direct anterior approach.