The Journal of Arthroplasty, ISSN: 0883-5403, Vol: 26, Issue: 7, Page: 1057-1060

Acetabular Revision Total Hip Arthroplasty Using an Impacted Morselized Allograftand a Cementless Cup Minimum 10-Year Follow-Up

Lee, Joong-Myung; Nam, Hee-Tae
Hip

This study was undertaken to analyze the clinical and radiologic results of acetabular revision arthroplasty using an impacted morselized allograft and a cementless cup and was performed on 71 hips of 62 patients who were followed up for a minimum of 10 years (10 years to 14 years 8 months; mean, 12 years). The acetabular bone defects were classified using the American Academy of Orthopaedic Surgeons Committee on the Hip and Paprosky classifications. Cementless hemispherical cups were inserted via a press-fit technique, using an impacted morselized allograft. The mean Harris hip score at the last follow-up visit was 92. Only 3 cases were re-revised, and the 12-year survival rate was thus 95.8%. The study shows that acetabular revision arthroplasty using an impacted morselized allograft and a cementless cup is an excellent treatment option.


Link to article