International Orthopaedics October 2013, Volume 37, Issue 10, pp 1905–1910

Acetabular cup positioning in revision total hip arthroplasty with Paprosky type III acetabular defects: Martell radiographic analysis

Choi, HR., Anderson, D., Foster, S. et al.
Hip

Purpose

This study evaluates acetabular cup position in the setting of revision total hip arthroplasty (THA) with severe acetabular bone defects.

Methods

With a definition of safe zone of abduction (30–50°) and anteversion (5–25°), acetabular cup position was measured by a digital image analysis program for 34 patients with Paprosky type III acetabular bone defects.

Results

There were 24 cups (71 %) for abduction and 26 cups (76 %) for anteversion located in the safe zone. Nineteen cups (56 %) were within the safe zone for both abduction and anteversion. There was no dislocation, however one cup out of the safe zone resulted in early cup failure due to aseptic loosening.

Conclusions

The acetabular cup positioning in patients with Paprosky type III defects was ‘optimal’ in half of the cases. The prevalence of optimal acetabular cup position was similar to those reported in primary THA, suggesting that the presence of a large acetabular bone defect may not be a significant risk factor for suboptimal acetabular cup positioning in the setting of revision THA.


Link to article