caret
Otsikko caret Julkaisija caret Vuosi caret Info caret
Clinical Trials in the Gene Therapy of Arthritis Evans, C. H. PhD*; Ghivizzani, S. C. PhD*; Herndon, J. H. MD*; Wasko, M. C. MD**; Reinecke, J. PhD†; Wehling, P. MD†; Robbins, P. D. PhD‡ 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p S300-S307 Open
Breakout Session 10: Osteoarthritis McIlwraith, C. Wayne BVSc, PhD; Frisbie, David D. DVM, PhD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p S311-S312 Open
Innovation in Total Hip Replacement—When is New Better? Walker, Peter S. PhD 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 9-25 Open
Influence of Cement Technique on the Interface Strength of Femoral Components Shepard, Michael F. MD*; Kabo, J. Michael PhD**; Lieberman, Jay R. MD† 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 26-35 Open
Particulate Bone Grafting of Osteolytic Femoral Lesions Around Stable Cementless Stems Benson, Eric R. MD; Christensen, Christian P. MD; Monesmith, Eric A. MD; Gomes, Sherry L. RN; Bierbaum, Benjamin E. MD 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 58-67 Open
Selection of Bone Grafts for Revision Total Hip Arthroplasty Goldberg, Victor M. MD 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 68-76 Open
Extensile Exposures for Revision Hip Arthroplasty Blackley, Hugh R. MB, ChB*; Rorabeck, Cecil H. MD** 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 77-87 Open
Argument Against Use of Food Additives for Osteoarthritis of the Hip Callaghan, John J. MD; Buckwalter, Joseph A. MD; Schenck, Robert C. Jr. MD 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 88-90 Open
Assessment of Patient Selection Criteria for Treatment of the Infected Hip Arthroplasty Hanssen, Arlen D. MD*; Osmon, Douglas R. MD** 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 91-100 Open
Limited Role of Direct Exchange Arthroplasty in the Treatment of Infected Total Hip Replacements Jackson, Walter O. MD*; Schmalzried, Thomas P. MD** 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 101-105 Open
Survey of Patient-Oriented Total Hip Replacement Information on the World Wide Web Mabrey, Jay D. MD 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 106-113 Open
Technical Considerations of Cemented Acetabular Components: A 30-Year Evaluation Crites, Brian M. MD; Berend, Michael E. MD; Ritter, Merrill A. MD 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 114-119 Open
Noncemented Acetabular Component Removal in the Presence of Osteolysis: The Affirmative Mallory, Thomas H. MD*‡; Lombardi, Adolph V. Jr. MD**; Fada, Robert A. MD†‡; Adams, Joanne B. BFA‡; Kefauver, Cheryl A. RN‡; Eberle, Robert W.§ 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 120-128 Open
Erythrocyte Transfusion Causes Immunosuppression After Total Hip Replacement Kendall, Susan J.H. PhD*; Weir, Justin MBBS*; Aspinall, Richard PhD**; Henderson, Don PhD**; Rosson, John MS* 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 145-155 Open
Radiographic Comparison of Diaphyseal Grit Blasted With Smooth Surface Stems by Matched Pair Analysis Min, Byungwoo MD*; Longjohn, Donald B. MD**; Dorr, Lawrence D. MD†; Wan, Zhinian MD† 2000 Clinical Orthopaedics and Related Research: December 2000 - Volume 381 - Issue - p 156-167 Open
The Safety and Efficacy of Intraoperative Heparin in Total Hip Arthroplasty DiGiovanni, Christopher W. MD*; Restrepo, Andrés MD*; Della Valle, Alejandro González MD‡; Sharrock, Nigel E. MB, ChB**; McCabe, John P. MD†; Sculco, Thomas P. MD*; Pellicci, Paul M. MD*; Salvati, Eduardo A. MD* 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 178-185 Open
Total Hip Arthroplasty Using a Ceramic Prosthesis Sedel, Laurent MD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 3-11 Open
Alternate Bearing Surfaces in Total Joint Arthroplasty: Biologic Considerations Archibeck, Michael J. MD*; Jacobs, Joshua J. MD*; Black, Jonathan PhD** 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 12-21 Open
Ceramic Femoral Head Retrieval Data Willmann, Gerd MS, PhD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 22-28 Open
Ceramic Component Failure and the Role of Proof Testing Pfaff, Hans-Georg; Ing, Dipl 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 29-33 Open
Clinical and Hip Simulator Comparisons of Ceramic-on-Polyethylene and Metal-on-Polyethylene Wear Clarke, Ian C. PhD*; Gustafson, Allen MD** 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 34-40 Open
Modern Ceramic-on-Ceramic Total Hip Systems in the United States: Early Results Garino, Jonathan P. MD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 41-47 Open
Evolution of Alumina-on-Alumina Implants: A Review Sedel, Laurent MD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 48-54 Open
Ceramic Hip Prostheses in Young Patients: A Retrospective Study of 74 Patients Fenollosa, Joaquin MD, PhD; Seminario, Pablo MD; Montijano, Cosme MD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 55-67 Open
As part of a search for better articulation in total hip prostheses, the decrease in the thickness of the socket in different total hip prostheses was measured in vivo. The wear rates of (1) RCH 1000 (molecular weight, 106) socket gammairradiated with 100 Mrad articulating with a crude COP (stainless steel containing 20% cobalt and 0.01% phosphorous) metal femoral head; (2) RCH 1000 socket nonirradiated articulating with a crude COP femoral head; (3) RCH 1000 socket irradiated with 100 Mrad articulating with an alumina femoral head; (4) ultra high molecular weight polyethylene (molecular weight, 5–6 × 106) socket articulating with an alumina femoral head; and (5) ultrahigh molecular weight polyethylene socket articulating with a stainless steel femoral head (T-28) were 0.06, 0.30, 0.06, 0.10 and 0.25 mm/year, respectively, in the authors’ clinical cases. Alumina femoral heads were effective in decreasing wear of the polyethylene socket. However, the wear rates of gamma-irradiated sockets articulating with alumina and with metal femoral heads wear very low and were not different from each other. Regarding the relationship between wear rate and the thickness of the ultra high molecular weight polyethylene socket articulating with a 28 mm alumina femoral head, on radiographs, average wear rates of socket thicknesses of 7, 8, 9, 10 and 11 mm were 0.14, 0.15, 0.12, 0.06, and 0.08 mm/year, respectively. On measuring retrieved prostheses, average wear rates of 7, 8, 9 and 11 mm thickness sockets were 0.2, 0.19, 0.14, and 0.1 mm/year, respectively. The wear of sockets has been proven to be minimal in alumina femoral heads articulating with ultrahigh molecular weight polyethylene sockets thicker than 10 mm. Bizot, Pascal MD; Banallec, Laurence MD; Sedel, Laurent MD; Nizard, Remy MD, PhD 2000 Clinical Orthopaedics and Related Research: October 2000 - Volume 379 - Issue - p 68-76 Open