International Orthopaedics August 2004, Volume 28, Issue 4, pp 193–197

Minimally invasive unicompartmental knee replacement with a nonimage-based navigation system

Perlick, L., Bäthis, H., Tingart, M. et al.
Knee

In a prospective study, two groups of 20 unicompartmental knee replacements (UKR) each were operated either using a CT-free navigation system or the conventional minimal invasive technique. Radiographic assessment of postoperative alignment was performed by long-leg coronal and lateral radiographs. The results revealed a significant difference between the two groups in favor of navigation. In the computer-assisted group, 95% of UKRs were in a range of 4–0° varus (mechanical axis) compared with 70% in the conventional group. The only inconvenience was a prolonged operation time (+19 min). Due to the limited exposure, the navigation system is helpful in achieving a more precise component orientation. The danger of overcorrection is diminished by real-time information about the leg axis at each step during the operation.